3.2 IRTransmitter
SwitchontheIRTransmitterandcheckconditionofbatteriesthrough flashingofGREENLED
nexttooptics;conditionisindicatedbynumber offlashes:
10=FullCharge
1=AlmostFlat.
Redlight=meansthatbatteriesshouldbechangedimmedia tely!
Endofbatterytestisindicatedbyseriesofgreen/yellowlightsalternatingquickly.
(Batterytestiscarriedoutbydeviceautomatically.)
3.3 “SightAim”theIRTransmitterLensindirectionoftheIRReceiverLens.
3.4 IRReceiver
GototheIR Receiverand“SightAim”IRReceiverroughlyinitsfinalposition&thenswitchon
3.5 Ifbatterieshaveinsufficientcharge,thenaflashingredlightwillactivate,otherwiseyoushould
seeasolidREDlight.
3.6 AdjusttheIRReceiverbyturningtheopticlensinthedirectionofIRTransmitter,sotheycan
communicate.Whenthelensalignmentiscorrect&thedevicesarecommunicatingcorrectly,
thenthecolourofLEDwillchangetosolidGREEN.
3.7 Thesystemwillactivateandbereadytousewhenacontinuousinfra‐connectionexistsfor
longerthan15seconds(continuousgreenlight)
3.8 Youcancheckifthesystemistriggeringcorrectlybywalking/crossingtheinvisibleinfra‐rayline
withthe15secondperiodandtheLEDlightwillturnRED
3.9 AfterSystemActivationthesystemwillthenchecktheGSM‐connection(ittakesabout1
minute);thisprocessisindicatedbyflashinggreenlig hts.
AftertheseflashesacontinuousgreenlightmeansthatGSM‐connectionisbuilt ‐up.
Endofthisprocessisindicatedbygreen/yellowlights.
Withinafewminu tes you´llgetanSMSinformingyouonexactfieldintensityattheplaceofthe
trap,conditionsofbatteriesandnormal operationofdevice.
3.10 Wait1minuteandcheckoperationbycarringoutatestalarm(crossingtheinfra‐raypath).
YoushouldreceiveaSMSwith“Alarm”
3.11 TheCS‐miniLEDlightswillautomaticallyturnoffaftera5minuteperiodtoavoiddetectionby
otherpersons.